Add to Cart
Car Navigator I2C 10 Inch Touch Screen Panel With Black Prints
Size: | 10.1 inch |
Total Thickness: | 2.0±0.2mm |
Outline of Cover Lens: | 251.96*146.64±0.1mm |
Outline of ITO Sensor: | 246.8*145.64±0.2mm |
Viewing Area: | 221.1*125.78±0.2mm |
Active Area: | 222.1*126.78±0.3mm |
TP Structure: | G+G |
Controller: | Goodix 9271 |
Cover glass thickness: | 0.7mm, 1.1mm, 1.8mm, 2mm, 3mm (Optional) |
Cover glass treatments: | AG, AR, AF, AE (Optional) |
CTP interface: | IIC |
Operating system: | Android, Linux |
Working temperature and humidity | -20°C~70°C,20~85% RH, non-condensing |
Storage environment and humidity : | -30°C~80°C, 20~85% RH, non-condensing |
Transparency | ≥85% |
Response time: | <10ms |
ESD Air discharge: | 8KV |
ESD Contact discharge: | 4KV |
Pen hitting life: | ≥10,000,000/point |
Pen sliding Durability: | ≥500,000 times |
Finger Touch life: | ≥35,000,000 times |
Certifications: | CE, FCC, Rohs |
Aspect ratio: | 16:9 |
Report rate: | 100HZ |
Input method: | Finger or capacitive pen |
Warranty: | 1 Year |
Project proceeded steps
1. Receipt of customer’s RFQ ( detailed requirements of the touch panel, qty. Needed etc.)
2. Evaluate the drawing and offer the redesigned drawing and quotation to the customer.
3. Confirm the drawing and quotation.
4. Go ahead with sample manufacturing
5. Samples’ testing and confirmation of samples
6. Mass production
7. Shipment, follow up with the feedback of mass production.
RFQ:
1. What’s your lead time?
Re: The lead time for both samples and mass production is 15 days.
2. Are you a trading company or manufacturer?
Re: We are a manufacturer.
3. What kind of products can you provide?
Re: We can provide capacitive touch panel from 3.5” to 86” and optical bonding products.
4. How to deal with the defective touch panel after they are shipped.
Re: First, we will make clear what the issue is. Usually the issue can be solved by either remote testing or sending back representative defective touch panels.
Reliability Test
Touch Panel Reliability Test Condition | ||||
1. Set the initial temperature to be 25℃ 2. Ramp to 80℃at 90% RH, 2H 3 .Soak at 80℃at 90% RH, 2H 4. Ramp from 60℃at 90% RH to -20℃, 4H 5. Soak to -20℃, 2H 6. Ramp from -20℃to 25℃, 2H
| Condition | Temp. | Humidity | Time |
Intitial condition | 25℃ | / | / | |
Ramp to 80℃ | 60℃ | 90% | 2H | |
Soak | 60℃ | 90% | 2H | |
Ramp to -20℃ | -20℃ | / | 4H | |
Soak | -20℃ | / | 2H | |
Ramp to initial temperature | 25℃ | / | 2H | |
12H for each cycle(from step 1 to 6), total 28 cycles. | Duration of one circle | 12H |